Detect visible defects while film, sheet or coated material moves through production, alongside roll sampling and downstream quality checks. Scantech SHF3 VI places defect-detection cameras within the scanner-frame beams and can combine visual inspection with application-configured web measurement for a more complete view of production performance.

ScantechAuthorized Scantech sales & applications support partner. Gauge Advisor helps define the defect library, required web measurements, frame requirements, sample review, integration scope, and commercial configuration.
Scantech SHF3 VI scanner with integrated visual inspection for continuous webs
Super Heavy Frame 3 · Visual Inspection. Cameras are integrated within the frame beams so visual inspection can be coordinated with application-configured web measurements.
Transparent or opaqueScantech identifies optical inspection applications for both transparent and opaque materials.
Cameras in the frameDefect-detection cameras are located inside the scanner-frame beams.
Visual + measurementVisual inspection can be combined with the web-measurement technology configured for the application.
Wide-web systemThe frame is configured to the web width, access, environment, and measurement requirements.
Continuous production inspection

Add visual inspection to the moving web

Start with your material, examples of the defects you need to find, line conditions and measurement goals. Those details determine the camera and scanner configuration.

01

Define the web and defect

Document material structure, transparency or opacity, width, speed, surface condition, and known good, borderline, and reject events.

02

Present the moving web

Confirm passline, stability, tension, flutter, inspection location, access, environment, and how the defect appears under realistic conditions.

03

Configure vision and measurement

Confirm the SHF3 VI visual-inspection configuration and select any application-specific web measurement that must be coordinated with it.

04

Define evidence and response

Specify the required event review, data, alarms, communications, reporting, marking, rejection, or process response for the complete system.

Published defect examples

Test detection of your defects on representative web samples

Scantech lists the following SHF3 VI application examples. Sample testing confirms which defects can be detected on your material and line.

Contamination

  • Contamination
  • Dirt
  • Insects
  • Oil splashes

Localized material events

  • Burn dots
  • Gels
  • Holes

Surface and formation

  • Scratches
  • Streaks
  • Wrinkles

Optical condition

  • Opacity
  • Condensation

Detectability must be qualified for the real material and line

Detection depends on the defect size and contrast, material transparency, lighting, surface texture, reflectivity, web motion, camera setup and pass/fail criteria. Application testing establishes suitable detection limits and operating speed for your material; these limits are not the same for every application.

FlexScan TREX screen plotting web defects by position with selected-event details for Scantech SHF3 VI
Representative FlexScan/TREX software view for SHF3 VI, showing plotted defect events and selected-event details. Interface, available fields, categories, and retained data may vary by configuration and software release.
FlexScan / TREX event review

Review detected events in production context

The representative software view shows how detected events can be placed within the production history. Select a plotted event to review the available position, timing, size, category, type, and event-image information associated with that detection.

  • See detected events distributed by web position and production length
  • Select an individual event to open its recorded details
  • Review displayed fields such as X position, time position, metering position, size, category, and type
  • Use the selected-event image area to support operator and quality review

Available fields, event categories, image handling, communications, alarms, and response functions are confirmed for the quoted software and system configuration.

Related process signals

See visual defects and web measurement together

SHF3 VI is designed to combine classic measurements and visual inspection. The measurement technology is selected for the actual material and production objective; it is not automatically identical in every frame.

Visual inspection answers

What happened on the visible web surface?

  • Is there contamination, a gel, hole, scratch, streak, wrinkle, opacity event, or another visible anomaly?
  • How should detected events be displayed and reviewed?
  • What evidence must operators or quality teams retain and review?
  • What alarm or downstream action should the complete system support?
Web gauging answers

What changed in thickness, weight, density, or profile?

  • Is the selected measurement inside the target and tolerance?
  • Is the cross-web or machine-direction trend changing?
  • Did the process create both a dimensional and a visual consequence?
  • Should the measurement support manual correction, reporting, or compatible automatic control?

Need thickness, basis-weight, density, or cross-web profile measurement?

Compare Scantech web-gauging sensors, scanners, software, reporting and compatible control options for use on their own or alongside visual inspection.

Explore web gauging systems
Scantech SHF3 VI

Configure the frame around the web and measurement requirements

The current English Scantech product page provides these dimensional starting points. Confirm the final frame, cameras, measurement heads, access, environment, and options in the current quotation.

Scantech SHF3 VI super heavy frame with integrated visual inspection
The product image shows the complete wide-web frame. Final frame width, access, cameras, measurement heads, environmental protection, and options are configured for the actual line.

Published configuration options include

Scanner cooling systemOdometerFrame pressurizationElectrical panel & headsExpansion-system feetThree-color indicator lightsThree-button remote-control box

Published configuration starting points

Current English Scantech product-page values; actual quotation and site review govern.

Product width
500–13,500 mm
Width increments
500 mm
Overall frame width
1,778–14,778 mm
Frame depth
450 mm
Frame height
1,600 mm
Access
Removable upright; hatch available
Visual inspection
Defect-detection cameras located inside the frame beams
Measurement system
Classic measurement technology selected and configured for the application
Preliminary application fit

Where SHF3 VI is a strong starting point

Use this as an initial routing guide. The actual material, defect library, speed, environment, camera configuration, and measurement requirements determine the final recommendation.

Strong starting candidate

Continuous web with a defined visual defect risk

  • Cast film and sheet, coating film, biax or MDO film, or battery-separator film
  • Defects create visible contrast or appearance changes
  • Transparent or opaque material
  • Continuous inspection adds value beyond roll sampling alone
  • Visual inspection and web measurement should share a coordinated frame design
Confirm with samples and line data

Optically or mechanically demanding applications

  • Very small, low-contrast, intermittent, or acceptance-critical events
  • Reflective, textured, printed, multilayer, or otherwise unusual surfaces
  • High speed, web flutter, harsh temperature, dust, vapor, or restricted access
  • Requirements for classification, image retention, marking, rejection, or process action
  • Unclear distinction between a visual defect and a dimensional/profile problem
Faster application review

What should you send for SHF3 VI testing and pricing?

Start with the material and defect examples. Then identify any additional measurements, records, alarms or production responses the system needs to provide.

  • Material, layer structure, and production process
  • Minimum and maximum web width
  • Normal and maximum line speed
  • Web-path drawing, passline, and available scanner space
  • Transparent, opaque, reflective, printed, textured, or coated condition
  • Known defect types and minimum meaningful defect dimensions
  • Good, borderline, and reject samples or representative images
  • Web tension, flutter, vibration, temperature, dust, vapor, and environment
  • Required thickness, basis-weight, density, or other web measurement
  • Required images, events, reports, alarms, communications, and retention
  • Marking, rejection, line-stop, PLC, MES, or process-action requirements
  • Current manual, camera, laboratory, and gauging reference methods
Common application questions

Scantech SHF3 VI web inspection FAQ

These answers provide a starting point. Current manufacturer data, line review, and representative materials govern the final configuration.

What does the Scantech SHF3 VI inspect?
SHF3 VI is a continuous-web scanner design that combines visual inspection with classic measurement technologies selected for the application. Scantech identifies use cases including film, sheet, coated films, biax film, and battery-separator film.
Can SHF3 VI inspect transparent and opaque webs?
Scantech states that its optical imaging can detect visual defects on transparent and opaque materials. Actual performance still depends on material response, contrast, surface, lighting, speed, defect size, and the configured system.
What types of web defects can it detect?
Scantech publishes examples including burn dots, condensation, contamination, dirt, gels, holes, insects, oil splashes, opacity, scratches, streaks, and wrinkles. These are examples, not guaranteed limits for every material or speed.
Is SHF3 VI automatically a thickness or basis-weight gauge?
Not every frame has an identical measurement configuration. SHF3 VI is designed to combine visual inspection with classic measurements, but the measurement head and outputs must be selected for the actual material, structure, range, and process goal.
Where are the visual-inspection cameras installed?
Scantech states that the defect-detection cameras are located inside the scanner-frame beams. Final camera, lighting, coverage, access, and environmental details are confirmed for the application.
How wide a web can SHF3 VI accommodate?
The current English Scantech product page lists product widths from 500 to 13,500 mm in 500 mm increments. Confirm the current available width, overall frame, access, and transport requirements in the quotation.
Does visual inspection replace laboratory or manual QA?
No. Continuous vision adds in-line inspection information, but it does not replace the manufacturer’s validation, challenge samples, acceptance rules, reference methods, false-accept and false-reject controls, or procedure for accepting or rejecting product.
Can the system trigger alarms, marking, or rejection?
Those functions must be defined as complete-system requirements and confirmed with Scantech. Public product information does not establish one universal alarm, marking, rejection, classification, or plant-integration configuration for every SHF3 VI application.