Laser Micrometers & Laser Diameter Gauges
LaserLinc laser micrometers measure outside dimensions without touching the product. Compare laser diameter gauges for tubing, wire, cable and extruded profiles. Choose an Axion single- or dual-axis system or a Triton triple-axis system based on the dimensions you need, then select the guides, software and control options for your line.
Authorized LaserLinc sales & applications support.Free LaserLinc phone & remote support for original purchasers, Mon–Fri, 8am–5pm Eastern. Gauge Advisor is also available during Pacific business hours.
- Non-contact measurement
- Inline or offline configurations
- Four-year micrometer warranty
- Application & integration support
Start with what the process must measure
Each measurement axis views the product from a different direction. Choose the number of axes based on the product shape and the dimensions you need, then select the measurement range, rate, guides, software and controls.
Triton 330
Three simultaneous views provide the strongest fixed-axis average OD and estimated-ovality performance for moving round and elliptical products.
- Range
- 0.102–29.2 mm / 0.004–1.15 in
- Rate
- 300/axis; 900 total
- Repeatability
- ±0.125 µm / ±0.000005 in, 2-sec avg
Axion 222
Two perpendicular measurement directions for simultaneous X/Y dimensions, width and height, and a directional estimate of ovality.
- Range
- 0.076–21.6 mm / 0.003–0.85 in
- Rate
- 400/axis; 800 total
- Repeatability
- ±0.125 µm / ±0.000005 in, 2-sec avg
Axion 130
A strong starting point when one projected dimension—such as OD or width—is the actual requirement. The separated transmitter and receiver also support mechanically constrained installations. Edge, gap, or position applications depend on product geometry and software configuration.
- Range
- 0.178–29.2 mm / 0.007–1.15 in
- Rate
- 1,600/axis; 4,000 optional
- Repeatability
- ±0.25 µm / ±0.00001 in, 2-sec avg
Need help with axis count? Product shape, orientation, wander, tolerance, and how the result will be used matter more than simply adding measurement axes.
Open the axis guide →What the laser sees—and what requires another method
A laser micrometer measures the outside shadow presented to each axis. Additional measurement technologies extend the system when the requirement involves internal geometry or the complete surface. Explore how micrometers detect diameter and shape defects with interactive examples.
Optical and laser micrometers: Optical micrometer is a broader term for non-contact dimensional measurement using light. LaserLinc uses scanning-laser technology; other optical systems use different illumination and camera or image-sensor arrangements. When comparing systems, specify the outside diameter, width or height, number of measurement axes, line speed and defect-detection requirement.
✓ Direct laser measurements
- Outside diameter and other projected outside dimensions
- X/Y diameter, width and height with the appropriate axes
- Estimated ovality with an appropriate dual- or triple-axis configuration
- Flat-to-flat dimensions and qualified edge, gap, or position measurements; runout requires controlled rotation and reference fixturing
- Dimensional variation along moving product
- Simultaneous tracking of multiple strands with a compatible Multi-Strand hardware and software configuration
→ Extend the measurement system
- ID, wall thickness, and concentricity require ultrasonic or another qualified method; review the medical-tubing path or the pipe & profile systems path
- Complete surface-defect inspection requires FlawSense or another dedicated technology
- Complete roundness profiles require information around the full circumference
- Automated full-length finished-part profiling requires controlled part presentation and motion
- Coating or layer thickness may require a coating-specific or ultrasonic method
Compare the complete laser micrometer range
Triple- and dual-axis systems lead because they are the more common starting points for moving round product and inline extrusion. Single-axis and split-frame models remain important when one projected dimension, a constrained installation, or a wider measurement range drives the application.
Swipe horizontally to compare all specifications.
| Model | System | Measurement range | Measurements/sec per axis | Published 2-sec averaged repeatability |
|---|---|---|---|---|
| Triton 312 | Triple axis | 0.102–11.4 mm / 0.004–0.45 in | 600 | ±0.125 µm / ±0.000005 in |
| Triton 330 Common | Triple axis | 0.102–29.2 mm / 0.004–1.15 in | 300 | ±0.125 µm / ±0.000005 in |
| Triton 331 | Triple axis | 0.254–27.2 mm / 0.010–1.07 in | 1,600; 4,000 optional | ±0.125 µm / ±0.000005 in |
| Triton 360 | Triple axis | 0.406–52.6 mm / 0.016–2.07 in | 1,600; 4,000 optional | ±0.5 µm / ±0.00002 in |
| Axion 203 | Dual axis | 0.04–2 mm / 0.00158–0.079 in | 1,200 | ±0.025 µm / ±0.000001 in |
| Axion 222 Common | Dual axis | 0.076–21.6 mm / 0.003–0.85 in | 400 | ±0.125 µm / ±0.000005 in |
| Axion 230 | Dual axis | 0.178–29.2 mm / 0.007–1.15 in | 1,600; 4,000 optional | ±0.125 µm / ±0.000005 in |
| Axion 260 | Dual axis | 0.406–56 mm / 0.016–2.2 in | 1,600; 4,000 optional | Published metric value and imperial conversion require confirmation |
| Axion 2120 | Dual axis | 0.7–114 mm / 0.028–4.5 in | 1,600; 4,000 optional | ±1.0 µm / ±0.00004 in |
| Axion 103 | Single axis | 0.015–2.2 mm / 0.0006–0.086 in | 1,200 | ±0.025 µm / ±0.000001 in |
| TLAser 122 | Single axis | 0.038–22 mm / 0.0015–0.866 in | 400 | ±0.125 µm / ±0.000005 in |
| TLAser 122s | Single axis | 0.076–22 mm / 0.003–0.866 in | 400 | ±0.125 µm / ±0.000005 in |
| Axion 130 Common | Single axis | 0.178–29.2 mm / 0.007–1.15 in | 1,600; 4,000 optional | ±0.25 µm / ±0.00001 in |
| Axion 160 | Single axis | 0.254–58 mm / 0.010–2.3 in | 1,600; 4,000 optional | ±0.5 µm / ±0.00002 in |
| Axion 1120 | Single axis | 0.711–116 mm / approximately 0.028–4.55 in | 1,600; 4,000 optional | ±1.0 µm / ±0.00004 in |
| Axion 1240 | Single axis | 0.914–231 mm / 0.036–9.1 in | 1,600 | ±2.0 µm / ±0.00008 in |
Specification note: Values are model- and configuration-dependent. Repeatability values shown are based on two-second averaging and should not be interpreted as measurement accuracy. Confirm final range, gate clearance, measurement rate, product-position allowance, and interface requirements during application review. The current datasheet includes specialty configurations that may require availability confirmation.
Build the system around the micrometer
Laser measurement can be integrated into an extrusion line, a compact benchtop station, or an automated finished-part inspection platform. These are complete workflows—not additional micrometer models.
Continuous line measurement
Axion or Triton heads can monitor moving product continuously and provide measurements for trending, alarms, operator adjustment, or qualified line control.
Build a medical tubing measurement profile →
BenchLinc OD/ID
Controlled sample presentation and fixturing support repeatable offline inspection of cut polymer-tubing samples, including OD, ovality, material thickness, and calculated ID.
Explore BenchLinc OD/ID →
BenchLinc UT
Ultrasonics measure wall thickness and concentricity offline. An available Triton configuration adds OD and estimated ovality for a more complete tubing profile.
Explore BenchLinc UT →
Metron automated inspection
Metron moves and, where required, rotates finished parts through selected measurement technologies to profile diameter, ovality, length, transitions, and localized dimensional variation. For catheter applications, see when to add rotation to a maximum OD scan.
Explore Metron →Companion technologies: UltraGauge measures wall thickness ultrasonically and derives concentricity or eccentricity from the wall profile; paired laser OD supports calculated ID. FlawSense is a separate laser-line-triangulation technology for true 360-degree dimensional surface inspection—not a micrometer accessory.
Compare surface-inspection technologies →
Use measurements for trends, alarms and process control
Total Vu gives the operator a live view of what the laser micrometer measures. You can set product limits, save results, and see how readings change during a run. The screens, inspection steps, and reports can be tailored to your process, with options for OPC UA connections and closed-loop control.
- Live values & tolerance status
- Trends, SPC & statistics
- Recipes & production records
- Alarms & control functions
Match the interface to the job. SmartLinc Display fits benchtop spot checks without saved measurement data. SmartLinc Processor sends tags to an existing machine system. Choose Total Vu when your team needs custom screens, guided inspection, trends, SPC, saved results, reports, or coordinated process control.
SmartLinc Processor
Send Axion and Triton measurement tags to your existing PLC, HMI, or machine software. Processor fits inline integration and custom benchtop projects that already have their own screens, records, and control logic.
Explore SmartLinc Processor →
SmartLinc Display
Read live dimensions on a dedicated benchtop touchscreen for quick spot checks. SmartLinc Display does not save or export measurement data.
Explore SmartLinc Display →Available communications may include EtherNet/IP, Modbus TCP, OPC UA, Siemens S7, TCP/IP, UDP, and RS-232 depending on the selected hardware and software configuration. Confirm the required PLC, HMI, reporting, and plant-level interfaces during application review.
Make the measurement repeatable in the real process
The measurement head is only one part of a reliable station. Product motion, alignment, environment, mounting, and length feedback can have as much influence on the result as the model number.
Product guidance & fixturing
Roller guides, feed-through guides, and V-blocks help flexible or moving product remain appropriately positioned through the measurement field. See how part alignment affects diameter readings.
Installation & alignment
Adjustable stands and application-specific mounts establish a stable, serviceable measurement location and support line alignment.
Optics protection
Air-purge and window-guard options help protect the optical path from dust, mist, debris, and accidental contact. Air purges require clean, oil-free air.
Length-correlated measurement
Encoder-equipped roller and fixture options relate dimensional events to production length or part position when supported by the complete configuration.
Long V-blocks, multistrand guides, dual and triple mounts, specialty feed-through fixtures, and custom mounting options are also available for qualified applications.
Review my installation →Laser measurement across different production processes
Use the market-specific solution pages and selectors for inspection methods, complementary equipment and quality requirements specific to your product.
Medical tubing, catheters & guidewires
OD, estimated ovality, tapers, profiles, and coordinated wall or surface inspection.
Medical solutions → 02 / Wire & cableWire, cable, fiber & monofilament
Continuous diameter, estimated jacket ovality, and—when appropriately configured—multi-strand measurement and process control.
Wire & cable solutions →Pipe, hose, tubing & profiles
Non-contact dimensional monitoring for rigid and flexible products, including pipe, tubing, hose, cord, seals, and qualified profiles.
Ribbon, multiple strands & special geometry
Width, height, flat-to-flat distance, and qualified gap, position, or multiple-strand applications.
Compare axis configurations →What determines laser micrometer price?
A complete system quote depends on the measurement range and axis count, plus the display or data interface, product guides, mounting, software, and integration needed for your process. An inline monitoring station and a bench inspection system can require different configurations. For a starting budget by axis count, see the laser micrometer cost guide.
Start with these three details. I will review the application, identify the likely configuration, and clarify any remaining information needed for a system quotation. Gauge Advisor welcomes LaserLinc equipment inquiries worldwide and coordinates application review and quotation support with the appropriate manufacturer team.
Request a LaserLinc quote →What to send for equipment selection and pricing
After the initial review, these details help confirm the measurement range, axis count, rate, mounting, product handling, software, and controls. You do not need every answer to start a quotation request.
Share the values you know, even if the specification is incomplete. Gauge Advisor can help compare equipment options and identify what needs sample testing or further confirmation.
Send application details →Continue the evaluation
Use the technical guides and tools for deeper geometry, calibration, troubleshooting, and application-specific selection. See how to choose calibration pin sizes for a worked OD example. If you already have a gauge, explore on-site laser micrometer calibration and verification support.
Single vs. dual vs. triple axis
Understand what each measurement direction sees and where orientation matters.
Open guide → CalculatorCalibration pin planning tool
Plan reference sizes around the product range and calibration procedure.
Use calculator → Diagnostic toolMicrometer troubleshooting assistant
Work through alignment, contamination, vibration, positioning, and signal issues.
Start diagnostic → Application selectorMedical tubing measurement selector
Screen OD, wall, ID, concentricity, profiles, and defect-inspection requirements.
Start selector →Working on pipe, hose, tubing, rod, or a profile? Start with the connected pipe & profile extrusion guide. For wire or cable, use the wire & cable measurement selector.
Laser micrometer selection questions
Is a diameter sensor the same as a laser micrometer?
How many measurement axes does my application need?
Can the same laser micrometer be used inline and offline?
Can a laser micrometer measure clear or transparent product?
Can it measure ID, wall thickness, or concentricity?
Is published repeatability the same as accuracy?
How should measurement rate be selected?
Do all micrometer systems require Total Vu?
What accessories should be included?
Get a practical starting configuration for your application
Share the product, dimensional range, tolerance, line speed, inspection method, environment, and data requirements. Gauge Advisor will help identify the likely measurement head, guiding, interfaces, software, and next validation step.
LaserLinc scanning laser micrometers and standard micrometer accessories carry a four-year warranty. Other system components, pass-through hardware, ultrasonic transducers, and custom-engineered products may have different terms. Final specifications and performance are application- and configuration-dependent.